Just 30" tall, it uses the same light assembly as our Lighthouse unit and can be equipped with two 20 amp GFI or two 30 amp marine receptacles, or a combination of 20 and 30 amp receptacles.
Power Pedestals provide a 360º light pattern. This light pattern is important in a marina because it lights both the marina dock and the finger piers, yet does not shine in the boats because it's directed downward. Best of all, the bulb will last about 3 years and cost about 30 cents per month to operate.
|
| |
|
|
| |
|
|
| |
|
|
|
|
|
|
|
"Five Years of development have yielded
the most innovative mini-power center available."
- Receptacles surface-mounted at top of unit for easy replacement and meets NFPA 303 3-14.1c 24" above the dock when mounted on a 30" dock box.
- Downward indirect lighting.
- Loopfeed copper bus bars. Internal electronic metering.
- Easy mounting brackets for piling, dockbox, pedestal or covered dock uprights.
- Phone& cable TV outlets available.
- 100% Lexan® Housing with lifetime warranty.
|
 |
|
|
|
|
|
| |
|
|
|
|
SURGE PROTECTION for POWER PEDESTAL
|
|
| |
|
|
| |
| Surgetrap™ is designed to protect electrical and electronic loads from transients and surge disturbances on your AC power line, such as voltage surges, spikes, and lightning.
|
- 175 KA Maximum Surge Current
- 3500 Joules
- UL/CSA Listed
- 3R Enclosure
- Comes with a Protection Working Indication Light
|
| |
The Surgetrap™ has a Lifetime Warranty where the device will be replaced at no extra charge. If you buy the power pedestal factory installed from the manufacturing facility, we will extend the warranty on all internal components of the Lighthouse, or Lighthouse SS power pedestal for three years as opposed to the two year warranty.
We can also provide you with the installation kit for the Lighthouse or Lighthouse SS Power Pedestal to retrofit your marina.
|
|
|
MARINA DISTRIBUTION CENTERS
|
|
| |
|
|
| |
|
|
|
SINGLE SUB-STATION
|
|
|
| |
|
DOUBLE - SIDE by SIDE SUB-STATION
|
|
|
| |
We now offer the Cutler-Hammer distribution panels as stand alone units or in one of our substations. All of our busses are made of copper and our breakers are the bolt-on type. Distribution panels can be 120/240V single-phase or 120/208V three-phase based on your system requirements. Distribution panels can also have a main breaker or a main lug. Branch circuit breakers are provided based on customer requirements.
|
- Double walled, Stainless Steel Housing with Polyester Powder Coating with a lifetime warranty
- Temperature Controlled Cooling Fans
- Copper Wound single and three phase transformer from 50KVA to 330KVA. It is double dipped in tough insulating varnish to protect the copper, an reduse noise.Then coated in high temperature epoxy to protect against the severe saltwater environment.
- Distribution Panel can handle up to 1200 AMP Main Circuit Breaker with (16) 120/240V Single-Phase or (11) 120/208V Three-Phase Branch Bolt-on Circuit Breakers connecting to a copper bus.
|
|
|
| |
|
|
| |
The one-of-a-kind Mega Yacht Unit meets the needs for all power requirement of large mega-yacht marinas. It includes all the standard features of the Marina specific transformer which provides both single and three phase power enclosed in a powder coated stainless steel enclosures. In addition to conveniently providing dual power, the Powerpoint unit reduces costs associated with installing separate power units. The Dual Phase Powerpoint allows for several options:
|
- Telephone, high-speed internet (RJ 45) and cable TV connections
- Water hose bib either single or dual 1/4 turn, 3/4” brass ball valves
- Dual water meters
- Digital Electronic Kilowatt metering
- Wireless remote reading of electronic kilowatt
- Meter socket to accept ring or ringless glass style meter
- Solar shield
- Various receptacle configurations available, see options below:
|
|
- 2 -100A 120/208V 3ø
- 2 -100A 480V 3ø
- 2 -100A 120/240V 1ø
- or any combination of single-phase receptacles up to 200A
|
|
| |
|
|
| |
|
|
| |
|
|
| |
We now offer a ground fault monitoring systems designed to detect fault currents in the AC shore power system that are too low to trip a circuit breaker. The Ground Fault Monitor helps reduce the risk of injury or property damage, which may result from stray fault currents. Our ground fault monitoring system provides information to the maintenance staff on the overall condition of the AC electrical system. The ground fault monitoring system operates 24-hours a day and can be monitored by non-technical personnel.
The monitor detects ground fault currents by means of current transformers (CT), which are placed around main or branch circuits. If a ground fault occurs, the CT will detect the amount of fault current and send a signal to the ground fault monitoring device where the amount of fault current is displayed with the faulty circuit identified. The detected fault can either activate an indicator alarm or disconnect the faulted circuit. Standard features include:
|
- Underwriters Laboratories listed current transformers
- Adjustable trip level 10mAmps to 10 Amps
- Current transformers up to 8 1/4” diameter
- Visual and/or audible alarm
- Housing of fiberglass (shown), or powder coated stainless steel available
|
| |
|
|
| |
|
|
| |
We now can offer our customers Cutler-Hammer PRL-3A & PRL-4 panels as stand alone units or in one of our substations. All of our busses are made of copper and are load rated, breakers are bolt-on type. Distribution panels can be 120/240V single-phase or 120/208V three-phase based on your system requirements. Distribution panels can also have a main breaker or a main lug. Branch circuit breakers are provided based on customer requirements.
Standard Features
|
- All InternalWiring is Fine Stranded 2000 Volt Insulated Copper
- Copper Buss Bars
- All Exterior Hardware is Stainless Steel
- Underwriters Laboratories listed
|
| Available Options |
- NEMA 3R, 4R, or 4X
- Powder Coated or Stainless Steel
- Main Breaker up to 1200 Amps
- Branch Breaker 20 Amps to 1200 Amps
- Main Lug Only
|
| Single-Phase |
- Single-phase up to 20 branch circuits
- Three-phase up to 14 branch circuits
|
| Three-Phase |
- Up to 1200 Amp Main Circuit Breakers
- Up to 10 Branch Circuit Breakers
|
| |
|
|
| |
|
|
| |
| Because of the high humidity and corrosive conditions of coastal environments, our transformers are wound with Class H heavily insulated copper bar and are double dipped in tough insulating varnish that protects the copper, as well as reduces the hum that is typical in a transformer that is not double dipped. For marine applications, we provide a third overcoat of high temperature epoxy to protect against the severe saltwater environment. We can also provide a custom transformer in single-phase or three-phase from 50 to 330 KVA. |
Standard features include:
|
- Copper wound transformer coils double dipped in high temperature baking varnish with epoxy overcoat for marina applications
- All copper to copper connections
- Fine stranded 2000V insulated copper
- Available Options:
- 50 to 330 KVA single-phase or three-phase
- Epoxy overcoat for non-marine applications
- Primary Voltages 480V 3ø Delta 3-Wire +G or 480V 1ø 2-Wire + G
- Secondary Voltages 127/220V 3ø Y 4-Wire, 120/208V 3ø Y 4-Wire, or 120/240V 1ø 3-Wire
- Single-phase in 50, 75, 100, 167.5, 200, 250 KVA
- Three-phase in 45, 50, 75, 112.5, 150, 225, 300 KVA
-
|
|
|
|
|